81-0328-01 Rev B
Doc-It® Life Science Software
Installation and User Instructions
Doc-It®LS Image Acquisition Software
Doc-It®LS Image Analysis Software
UVP, LLC Ultra-Violet Products Ltd
2066 W 11th Street, Upland, CA 91786 Unit 1, Trinity Hall Farm Estate
Tel: (800) 452-6788 / (909) 946-3197 Nuffield Road, Cambridge CB4 1TG UK
Fax: (909) 946-3597 Tel: +44(0)1223-420022 / Fax: +44(0)1223-420561
Web site: uvp.com
Przeglądanie stron 0
1 2 3 4 5 6 ... 110 111

Podsumowanie treści

Strona 1 - Web site: uvp.com

81-0328-01 Rev B Doc-It® Life Science Software Installation and User Instructions Doc-It®LS Image Acquisition Software Doc-It®LS Image Analysis Sof

Strona 2 - Table of Contents

Introduction 5 This system of usernames and passwords is separate from the one that is used to login to the computer. Setting up user accounts is

Strona 3

Performing Colony Counting 95 section of this manual for instructions on creating templates. Click Finish to exit the manual count mode. The softw

Strona 4

Performing Colony Counting 96 Delete Colonies Users may delete colonies after performing the initial count. To delete colonies, ensure that the

Strona 5

Performing Colony Counting 97 Merging Colonies Users may merge colonies after performing the initial count. Colonies should be merged when one colo

Strona 6 - Introduction

Performing Colony Counting 98 In the Spiral Plate Analysis window move the Overlay Size slider bar to the left (to decrease the grid size) or to th

Strona 7 - Minimum System Requirements

Performing Colony Counting 99 Click OK. If using the software for the first time, no templates are created and the User Defined Template Count op

Strona 8 - On the Fly Activation

Performing Colony Counting 100 Statistics In the Statistics tab of the Show Results window, information is displayed which shows the Statistical p

Strona 9 - Single-User License

Printing Reports and Images 101 Printing Reports and Images Printing Image Information File Print Command Exporting and Printing Colony Count Re

Strona 10 - Usernames and Passwords

Printing Reports and Images 102 Print Images can be printed to any Windows-supported printer, regardless of it being a file-printer, local printer or

Strona 11

Supporting 21 CFR Part 11 Compliance 103 Supporting 21 CFR Part 11 Compliance Purpose US - Food and Drug Administration (US-FDA) created and released

Strona 12 - Technical Support

Supporting 21 CFR Part 11 Compliance 104 opens with various types of reports available. To print the Audit Trail, click the Image History item. To

Strona 13 - License Agreement

Introduction 6 Enter a password. On initial installation, a screen will pop up to request a password and password confirmation. A password is requi

Strona 14 - Limitation of Liability

Glossary 105 Glossary Artifact: In imaging, a flaw caused either by the imaging process or by the hardware itself. For example, dust on the camera len

Strona 15 - Navigating the Software

Glossary 106 Pseudocolor: Artificial application of color to a non-color (monochrome) image, or artificial re-tinting of a colored image. Doc-It prov

Strona 16 - Toolbars

Introduction 7 Users Rights Depending on the privileges for the user that has logged onto windows, the following rights are available to that user fo

Strona 17

Introduction 8 License Agreement End User License Agreement PLEASE READ THE FOLLOWING AGREEMENT CAREFULLY This Agreement is between UVP, LLC of 2066

Strona 18 - Image Windows

Introduction 9 Limited Warranty and Disclaimer Licensor warrants the software and related documentation to be free from defects in materials and work

Strona 19 - Status Bar

Navigating the Software 10 Navigating the Software Main Window - Shows the full software screen Menus - Discusses the menus available Toolbars -

Strona 20 - Using Plug-In Modules

Navigating the Software 11 NOTE: Although most commands appear on the menus, some features are only available through the Plug-in Modules. If the Plu

Strona 21 - Positioning Plug-in Modules

Navigating the Software 12 Cut: Cuts a specific area Undo: Reverses the last command Redo: Repeats the last command Arrow: Selects an ann

Strona 22 - Digital Video Player

Navigating the Software 13 Rearranging Toolbars The order of the individual toolbar sections can be rearranged by placing the mouse arrow over the do

Strona 23 - Player Features

Navigating the Software 14 Showing the Image in Actual Size To show the image in actual size (no scaling), choose View > Zoom. Set the zoom factor

Strona 24 - Player Options

i Table of Contents Introduction...

Strona 25

Using Plug-In Modules 15 Using Plug-In Modules Overview The plug-in modules in LS allow the user to position modules on the work area for easy access

Strona 26 - Image Controls Plug-In

Using Plug-In Modules 16 Positioning Plug-in Modules Rearranging Plug-in Modules Plug-in Modules can positioned anywhere on the screen. Plug-ins c

Strona 27 - Change Gamma

Using Plug-In Modules 17 The center arrows console allows positioning of the plug-in module at the top, bottom, left or right of an empty workspace b

Strona 28 - 3D Plots

Using Plug-In Modules 18 If a sample is to be observed over a period of time it is required to snap multiple pictures at regular and definite tim

Strona 29 - Zoom/Pan

Using Plug-In Modules 19 Plays the sequence with a number of images to skip in reverse order. The number of images to skip can be set in the Options

Strona 30 - Magnify Part of an Image

Using Plug-In Modules 20 The other two ways this action can be initiated is: If the player is open, click on Extract from the player. If the pl

Strona 31

Using Plug-In Modules 21 Cancel: Closes the window and cancels the process. Saving .AVI Files If files need to be shared with another researcher

Strona 32 - Camera Plug-In

Using Plug-In Modules 22 Slide the Brightness control either left or right, or type a desired brightness value into the Brightness text box to the

Strona 33

Using Plug-In Modules 23 Invert Image Select the Invert check box. To stop inverting the image: clear the Invert check box Inverted Image Return to

Strona 34

Using Plug-In Modules 24 Y axis: The horizontal axis. X axis: The axis coming out of the plot, towards you. The plot can also be rotated by drag

Strona 36 - Creating Templates

Using Plug-In Modules 25 Go to View > Plugins to load the Zoom/Pan plug-in. Using Zoom In or Out Click on Zoom In or Zoom Out (located below

Strona 38

Camera Plug-In 27 Camera Plug-In The camera capture plugin provides camera controls for all Canon digital color cameras. To open the capture tab, g

Strona 39 - Editing Images

Camera Plug-In 28 Template: This button allows users to define templates to save customized setting and displayed features. Set-Up Canon Capture T

Strona 40 - Undo and Redo

Camera Plug-In 29

Strona 41

Capturing Images 30 Capturing Images This topic discusses the process of capturing images using LS software. The following sections explain the proce

Strona 42 - Using Image Filters

Creating Templates 31 Creating Templates Set-Up Templates Templates enable users to configure specific settings along with unique designator name to

Strona 43 - Background Filter

Creating Templates 32 selected. If a setting (or group of settings) is not excluded, it can be overridden on the Canon Camera plug-in before each cap

Strona 44 - Flip Image

Creating Templates 33 Click on the Count button to proceed to the Step 2 of 2: Finish tab. If the shape and size sliders are changed to capture a

Strona 45 - Image Enhancement Filters

Editing Images 34 Editing Images Overview Undo and Redo Copy Paste and Paste Special Using Selection Tools (Region of Interest Tools) Overvi

Strona 46 - Image History

iii Navigating 1D Analysis ...

Strona 47 - Measurement Tools

Editing Images 35 Paste This command takes an image from the clipboard and imports it into the software, displaying it in a new Image window. Note:

Strona 48 - Merging Two Images

Editing Images 36 Using the Region of Interest Tools Using the Selection Tools These tools allow users to mark part of the image for use in other

Strona 49 - Obtaining Image Information

Using Image Filters 37 Using Image Filters Overview Filter Navigation Image Filter Background Correction and Subtraction Overview LS Software

Strona 50 - Pseudocolor

Using Image Filters 38 Geometry Filters Rotate: Rotates the image around its center, useful for aligning images taken with a crooked gel. Align:

Strona 51 - Resize Image

Using Image Filters 39 Burn Changes to a New Image The Burn Changes to a New Image command takes all the changes made to the image and creates a dup

Strona 52 - Rotate and Align Image

Using Image Filters 40 Flip Vertically This image filter mirror-images an image, top for bottom. Unlike most image filters, it does not degrade the i

Strona 53 - Scanning Images

Using Image Filters 41 Click onto Sharpen from the Filters plug-in or use the Image > Filters > Sharpen command. Sharpening a large image may

Strona 54 - Spatial Calibration

Using Image Filters 42 Viewing Image History Each material change to an image is tracked in LS software s Image History feature. Material changes inc

Strona 55

Using Image Filters 43 measurement value. Right click on the new measurement annotation displayed to change the appearance of the annotation. If d

Strona 56 - Annotations

Using Image Filters 44 Tip: Paste Special also is available from the Toolbar and the Image window's shortcut menu. If the incoming image is

Strona 57 - New Annotation Window

iv Printing Image History...

Strona 58 - Selecting Annotations

Using Image Filters 45 To Enter Notes Display the Image Information window as described above. In the Properties tab, type information into the N

Strona 59

Using Image Filters 46 SYPRO Orange: Mimics the colors that appear with a SYPRO Orange stain. SYPRO Red: Mimics the colors that appear with a SYP

Strona 60 - Deleting Annotations

Using Image Filters 47 Tip: There is little point to increasing an image's size, although the filter does support it. Such an image would have

Strona 61 - Creating Annotations

Using Image Filters 48 Align an Image Align tool rotates the grid overlaid on the image so that it can be aligned with vertical/horizontal features

Strona 62 - Loading and Saving Images

Using Image Filters 49 Scan an Image from a Scanner Select Image > Scan > Start Scanning. Change any settings offered by the device as desi

Strona 63 - Image File Types

Using Image Filters 50 down list) first. For example, if the sample width of the image is 500 cm, select centimeters. Type the number of metric uni

Strona 64 - The Extended Attributes File

Annotations 51 Annotations Overview Annotations allow users to notate areas of an image without changing the image itself. This means that areas in th

Strona 65 - Performing 1D Analysis

Annotations 52 Ellipse: Ellipse annotations are very similar to Rectangle annotations except that they are oval rather than rectangular. Select the

Strona 66

Annotations 53 Click OK. Selecting Annotations After creating an annotation, select it either to change formatting properties or to graphically mov

Strona 68

Introduction 1 Introduction Welcome Life Science (LS) software from UVP lets users acquire, enhance, and analyze images in a simple and efficient wa

Strona 69

Annotations 55 Formatting Annotations The Annotation Formatting menu contains options to format a selected annotation. Change the formatting of an a

Strona 70 - 1D Analysis Settings

Annotations 56 Creating Annotations Creating a Text Annotation Select Tools > Add Annotation > Text. Click the position on the image to

Strona 71 - Resize Band Extents

Loading and Saving Images 57 Loading and Saving Images Loading Images LS Software will load images in popular formats, including JPEG, TIFF, GIF, PNG,

Strona 72 - Delete Lanes and Bands

Loading and Saving Images 58 To Save Using a Different File Folder, Name or Type From the File menu choose Save As. The Save window will appear.

Strona 73 - Lane and Band Information

Loading and Saving Images 59 compression formats. By comparison, a lossless format does not store as compactly, but also does not change the image in

Strona 74 - Lane Profile Graph

Performing 1D Analysis 60 Performing 1D Analysis Navigating 1D Analysis 1D Analysis Image Windows Features 1D Analysis Context Menu Commands 1

Strona 75 - Display Options

Performing 1D Analysis 61 Find Lanes and Bands: Searches for lanes and bands in the image. Edit Objects: Select, move and resize lanes, bands,

Strona 76 - Selecting Background Color

Performing 1D Analysis 62 1D Analysis Context Menu Commands The 1D Analysis context menu appears when 1D objects (lane, band, etc) are selected in t

Strona 77 - Filtering Data

Performing 1D Analysis 63 From the 1D Analysis toolbar menu or plug-in, click on Find Lanes and Bands. The Lanes/Bands dialog window appears and a

Strona 78

Performing 1D Analysis 64 On the Find Lanes and Bands window click Use auto-detected parameter values. The original parameters will be restored and t

Strona 79

Introduction 2 Minimum System Requirements Windows XP Professional with Service Pack-2 or higher (32 bit only), Vista (32 bit only), or Windows 7

Strona 80 - Export Data Explorer Reports

Performing 1D Analysis 65 1D Analysis Settings To access analysis settings, go to Analysis > 1D Analysis > Settings > 1D Analysis tab. Th

Strona 81

Performing 1D Analysis 66 Move the cursor over the image. A movable horizontal line will appear whenever the cursor is moved over a lane. Simply mo

Strona 82

Performing 1D Analysis 67 Place the mouse hand over the top or bottom of the band's extents and click and drag the box border to increase or t

Strona 83 - Specific Correction Options

Performing 1D Analysis 68 From the Analysis > 1D Analysis > Master Tools, click on Delete All Analysis Data or go to the 1D Analysis plugin &

Strona 84 - Concentration Calibration

Performing 1D Analysis 69 In this window, the software allows users to perform various changes to the lane including: Name Geometry Band Prope

Strona 85 - Unit Type

Performing 1D Analysis 70 Display Multiple Lanes The software has two options for displaying a multiple lanes. To Display Multiple Lanes by Selecting

Strona 86

Performing 1D Analysis 71 Underneath the graph and the lane image, in the Display options section, the following are available: Band Peaks: Select

Strona 87

Performing 1D Analysis 72 Viewing Data Explorer Results Printing Data Explorer Reports Exporting Data Fixed Image and Analysis Reports Overv

Strona 88 - Molecular Weight Calibration

Performing 1D Analysis 73 When selecting theses reports notice the various fields being selected/deselected from the list of data fields. Select from

Strona 89 - Using the Stretch Factor

Performing 1D Analysis 74 I-Max: Maximum intensity value reached within a lane. It actually shows the brightest (for black background) or darkest (

Strona 90 - Exact Placement of Bands

Introduction 3 On the Fly Activation To immediately activate the software through the Internet: Choose On the fly activation. If the computer is

Strona 91 - Adding Rf Lines Manually

Performing 1D Analysis 75 Reading the chart: The chart is read like a matrix, each cell value representing the computed/calibrated value for that b

Strona 92

Performing 1D Analysis 76 o To Excel o To CSV Click the To Excel or To CSV button. Name the file and click Save. Select a Report Type Summa

Strona 93 - Modify Dendrogram Graphs

Performing 1D Analysis 77 The Analysis Bands Report: Band Name and ID Calculated peak values (Rf value and molecular weight); Intensity of the

Strona 94 - Linkage rules

Performing 1D Analysis 78 Background correction is necessary to account for possible variable illumination or overexposure during image capturing,

Strona 95

Performing 1D Analysis 79 and quite distinct. Joined Valleys requires a sensitivity value to be entered. A higher value of sensitivity starts "

Strona 96 - Performing Colony Counting

Performing 1D Analysis 80 Graph display and units are easily modifiable by the user. The user may change the unit type or change the colors of the b

Strona 97 - Label Color

Performing 1D Analysis 81 Click Edit. The Edit window pops up. Change the concentration value to the desired number. Click OK. Deleting Data

Strona 98 - Manual Counting

Performing 1D Analysis 82 Note: Moving the bands or resizing them also changes their net intensity values. As a result, the user will see the word &q

Strona 99

Performing 1D Analysis 83 Molecular Weight Calibration Calibration of molecular weight (MW) involves associating a known standard with one or more

Strona 100 - Add Colonies

Performing 1D Analysis 84 In the Step 1: Select MW standard tab select the standard to copy. Then click on Copy. The Edit window will appear. Cha

Strona 101 - Split Colonies

Introduction 4 Offline Activation Select Offline Activation if the computer is not connected to the Internet. This allows the user to obtain the ac

Strona 102 - Spiral Counting

Performing 1D Analysis 85 Using Manual Placement of Weights If the user does not want to use the Stretch Factor, the weights can be adjusted individu

Strona 103 - Zone Analysis

Performing 1D Analysis 86 Retardation factor (Rf) Lines Automatic Rf Line Determination When two or more lines are calibrated with molecular weight

Strona 104 - Classes

Performing 1D Analysis 87 are red marks on the Rf line created, the Rf line will not be created when Confirm Add is selected. Ensure that the entire

Strona 105 - Distribution

Performing 1D Analysis 88 Overview Dendrograms are graphical/numerical displays used to show the similarity bands. The similarity is grouped into cl

Strona 106 - Printing Reports and Images

Performing 1D Analysis 89 Creating clusters Initially, each lane has its own cluster. Then, repeatedly, a linkage rule (see below) is used to merge

Strona 107

Performing 1D Analysis 90 http://marketing.byu.edu/htmlpages/books/pcmds/WARD.html Neighbor joining: At each stage of clustering the total branc

Strona 108 - Features

Performing Colony Counting 91 Performing Colony Counting The software offers several functions for counting colonies. Automatic Counting Manual Co

Strona 109

Performing Colony Counting 92 a line through the colony to be split o Auto Split Colonies – Allows users to split colonies by clicking on a colony t

Strona 110 - Glossary

Performing Colony Counting 93 Circle Radius To change the circle radius, click the drop down arrow and select from the numbers to change circle pixel

Strona 111

Performing Colony Counting 94 Manual Counting Step 1: Select Classes The window that appears after choosing Manual Count is the manual count windo